Answers are grounded in this paper and cite their sources.
Argon-fluoride (ArF) excimer laser operations at high repetition rates have been studied with special focus on the distance between electrodes. We find that, for stable laser operations, the maximum repetition rate increases with decreasing electrode separations. This is mainly caused by narrow discharge widths and an electric field intensity distribution that concentrates on the center. For an electrode separation of 8 mm, a homogeneous discharge could be maintained for an ArF excimer laser at a maximum repetition rate of 10 kHz. Results are discussed in detail with special focus on the influence of gas density depletion.
No takes yet. Share an insight, caveat, or question.
Ishihara et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: