Key result
A novel camera-based photoplethysmography algorithm using continuous wavelet transform denoising measured heart rate variability with a mean absolute error of 3.53 ms compared to an ECG chest band in static subjects.
Why the study?
Does a CWT-based denoising technique applied to chrominance-based photoplethysmography improve the accuracy of non-contact HRV measurement compared to existing methods?
Does a CWT-based denoising technique applied to chrominance-based photoplethysmography improve the accuracy of non-contact HRV measurement compared to existing methods?
Effect estimate: 3.53 ms
A novel camera-based photoplethysmography method using CWT-based denoising provides accurate, non-contact heart rate variability measurements comparable to contact devices.
BACKGROUND: The cardiac parameters, such as heart rate (HR) and heart rate variability (HRV), are very important physiological data for daily healthcare. Recently, the camera-based photoplethysmography techniques have been proposed for HR measurement. These techniques allow us to estimate the HR contactlessly with low-cost camera. However, the previous works showed limit success for estimating HRV because the R-R intervals, the primary data for HRV calculation, are sensitive to noise and artifacts. METHODS: This paper proposed a non-contact method to extract the blood volume pulse signal using a chrominance-based method followed by a proposed CWT-based denoising technique. The R-R intervals can then be obtained by finding the peaks in the denoised signal. In this paper, we taped 12 video clips using the frontal camera of a smart phone with different scenarios to make comparisons among our method and the other alternatives using the absolute errors between the estimated HRV metrics and the ones obtained by an ECG-accurate chest band. RESULTS: As shown in experiments, our algorithm can greatly reduce absolute errors of HRV metrics comparing with the related works using RGB color signals. The mean of absolute errors of HRV metrics from our method is only 3.53 ms for the static-subject video clips. CONCLUSIONS: The proposed camera-based method is able to produce reliable HRV metrics which are close to the ones measured by contact devices under different conditions. Thus, our method can be used for remote health monitoring in a convenient and comfortable way.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2016) studied Healthy (for HRV measurement validation) (n=6). Camera-based photoplethysmography with CWT-based denoising vs. ECG-accurate chest band was evaluated on Mean absolute error of HRV metrics (static subjects) (3.53 ms). A novel camera-based photoplethysmography algorithm using continuous wavelet transform denoising measured heart rate variability with a mean absolute error of 3.53 ms compared to an ECG chest band in static subjects.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: