In this study, we designed, fabricated, and evaluated a hard x-ray focusing mirror having an ideally focused beam with a full width at half maximum in the intensity profile of 36nm at an x-ray energy of 15keV. The designed elliptically curved shape was fabricated by a computer-controlled fabrication system using plasma chemical vaporization machining and elastic emission machining, on the basis of surface profiles accurately measured by combining microstitching interferometry with relative angle determinable stitching interferometry. A platinum-coated surface was employed for hard x-ray focusing with a large numerical aperture. Line-focusing tests on the fabricated elliptical mirror are carried out at the 1-km-long beamline of SPring-8. A full width at half maximum of 40nm was achieved in the focused beam intensity profile under the best focus conditions.
No takes yet. Share an insight, caveat, or question.
Yumoto et al. (2005) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: