Answers are grounded in this paper and cite their sources.
Information on concentrations of micropollutants (such as pharmaceuticals, pesticides, and industrial chemicals) in most highly dynamic riverbank filtration (RBF) systems is lacking, in contrast to data on standard chemical parameters. Sampling protocols have thus far been based on the stabilization of standard chemical parameters in relatively pristine environments. To determine whether groundwater samples for micropollutant analysis can be taken at a similar pumping volume as samples for testing standard chemical parameters in both environments, three groundwater monitoring wells in an RBF system were sampled at two points in time (after pumping of 3 well volumes and after pumping of 15 well volumes). Micropollutant concentrations were not significantly different between the two sampling points; therefore, appropriate samples can be drawn after pumping 3 well volumes. For a specific microbiological parameter (leucin incorporation), a statistically significant difference was found.
No takes yet. Share an insight, caveat, or question.
Driezum et al. (2017) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: