Answers are grounded in this paper and cite their sources.
The Bull Run supercritical unit was simulated by a linearized mathematical model based entirely on physical laws and design data, using an approach verified by comparison of an earlier simulation with field tests. A large set of differential and algebraic equations was solved to obtain transient responses. These responses were matched by transfer functions to obtain a process model which represented all significant plant inputs and outputs. In this study, appropriate use was made of a small digital computer, a large digital computer, and an analog computer. The process model of the Bull Run unit is believed to be the most detailed mathematical model which has been obtained for a supercritical electrical generation unit.
No takes yet. Share an insight, caveat, or question.
Littman et al. (1966) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: