Key result
In 48 patients with cemented glenoid components, progressive radiolucencies occurred mainly at the inferior pole, and RSA detected loosening in 3 of 5 patients after 3 years.
Why the study?
Does digital roentgen stereophotogrammetric analysis (RSA) improve the detection of early loosening of cemented glenoid components compared to traditional radiographs in patients undergoing total shoulder arthroplasty?
Observational (n=48)
Does digital roentgen stereophotogrammetric analysis (RSA) improve the detection of early loosening of cemented glenoid components compared to traditional radiographs in patients undergoing total shoulder arthroplasty?
Traditional radiographs underestimate early loosening of cemented glenoid components in total shoulder arthroplasty, and RSA is recommended for more accurate assessment.
Answers are grounded in this paper and cite their sources.
RSA may detect early glenoid loosening missed by radiographs after TSA; leaves open whether it should change surveillance or revision decisions.
The incidence of loosening of a cemented glenoid component in total shoulder arthroplasty, detected by means of radiolucent lines or positional shift of the component on true anteroposterior radiographs, has been reported to be between 0% and 44%. Radiolucent lines are, however, difficult to detect and to interpret because of the mobility of the shoulder girdle and the obliquity of the glenoid which hinder standardisation of radiographs. We examined radiolucencies around cemented glenoid components in 48 patients, with a mean follow-up of 5.3 years, and found progressive changes to be present predominantly at the inferior pole of the component. This may hold a clue for the mechanism of loosening of this implant. In five patients we performed an additional analysis of loosening of the glenoid component using digital roentgen stereophotogrammetric analysis (RSA). After three years, three of the five implants had loosened (migration 1.2 to 5.5 mm). In only one, with gross loosening, were the radiological signs consistent with the RSA findings. When traditional radiographs are used for assessment, the rate of early loosening is underestimated. We recommend that RSA be used for this.
No takes yet. Share an insight, caveat, or question.
Nagels et al. (2002) conducted an observational in Total shoulder arthroplasty (n=48). Cemented glenoid component was evaluated on Radiolucencies and loosening of the glenoid component. In 48 patients with cemented glenoid components, progressive radiolucencies occurred mainly at the inferior pole, and RSA detected loosening in 3 of 5 patients after 3 years.
Synapse has enriched 10 related papers. Consider them for comparative context: