Key result
Slow-pathway ablation successfully eliminated the tachycardia caused by double firing of dual-AV nodal pathways, resolving congestive heart failure symptoms and improving left ventricular ejection fraction.
Case Report (n=1)
Slow-pathway ablation can successfully treat tachycardia-induced cardiomyopathy caused by double firing of dual-AV nodal pathways presenting as wide complex tachycardia.
Answers are grounded in this paper and cite their sources.
Supports ablation as potential option for this rare tachycardia-induced cardiomyopathy; hypothesis-generating and should not yet change practice.
A 50-year-old woman presented to a different practice, in January of 2007, with a wide complex tachycardia, pulmonary edema, and left ventricular (LV) ejection fraction (EF) of 10%. Her coronary angiography was normal. She was initially placed on the heart transplant list. The tachycardia was difficult to manage but ultimately controlled with increasing doses of amiodarone, procainamide, and metoprolol. Her blood pressure and symptoms improved along with control of her arrhythmia. There was baseline left bundle branch block (LBBB), and a cardiac resynchronization defibrillator was implanted. She was continued on lisinopril, carvedilol, and amiodarone. Eight months after initial presentation, her LVEF was reported to have improved to 50%. She continued to do well until January of 2009, when amiodarone was discontinued due to abnormal liver function tests. Two months later, the patient presented with symptoms of congestive heart failure (CHF) and her LVEF had dropped to 25%. She was referred to electrophysiology for further evaluation. Her electrocardiogram (EKG) showed sinus rhythm with biventricular pacing and apparent frequent premature ventricular contractions (PVCs) in a bigeminal pattern. Device interrogation showed all normal parameters and around 50% biventricular pacing. There were nearly twice as many ventricular events than atrial events. Ventricular pacing was turned off to allow analysis during intrinsic conduction. This revealed a sustained wide complex tachycardia at 102 beats per minutes (Fig. 1). The tachycardia was suppressible with overdrive atrial pacing at a rate slower than the ventricular rate. We suspected that the patient had the same arrhythmia in 2007 leading to CHF. After review of her old records, we found an EKG (Fig. 2) with very useful information. What is the mechanism of her tachycardia? Presenting electrocardiogram after biventricular pacing was turned off. Electrocardiogram in 2007, when the patient presented with pulmonary edema. At first sight, the patient appeared to have frequent PVCs in a bigeminal pattern. Differential diagnoses include premature atrial contractions (PACs) with P wave buried inside of the T wave, junctional tachycardia or ectopies with retrograde block, recurrent single bundle branch reentrant beats, and double firing of dual-atrioventricular (AV) nodal pathways. There were several key observations in her EKG that raised doubts against PVCs. First, the bigeminal beats were very similar to her conducted sinus beat with LBBB. Second, there was variability in the coupling intervals of the bigeminal beats that was also associated with slight but consistent variability in QRS morphologies. These findings are very unusual for PVCs and strongly suggest an effect of supraventricular influence on the bigeminal beats. PACs were excluded with findings from device interrogation (more ventricular events than atrial events). Junctional tachycardia with retrograde block and any ectopies originated at or below the AV node can be essentially excluded by the fact that the arrhythmia was suppressible with atrial overdrive pacing at a rate slower than the ventricular rate. Therefore, the tachycardia can be best explained by the presence of dual-AV nodal physiology and double firing of sinus rhythm. It is conceivable that variability in slow and fast pathway conductions influences infra-His conduction as a form of gap phenomenon, leading to slight variability in QRS morphologies. The patient's EKG in 2007 (Fig. 2) was strongly supportive of double firing. Please note that the second half of the EKG showed 1:1 AV conduction with a long PR interval that is exactly the same of the P wave to the bigeminal beats in the first half of the EKG. The patient underwent an electrophysiology study in March of 2009. Double firing of dual-AV nodal pathways along with occasional Wenckebach physiology was observed (Fig. 3). All ventricular events were preceded by His signal with constant His-ventricular intervals. A conventional comprehensive study showed no baseline ventriculoatrial conduction and clear presence of dual-AV nodal physiology. The tachycardia was successfully eliminated with slow-pathway ablation by conventional technique. Her symptoms of CHF resolved almost immediately. Four months after ablation, her LVEF has returned to 45%. Due to persistence of mild-LV dysfunction and baseline LBBB, biventricular pacing was reprogrammed back on. The patient has remained asymptomatic and active since the time of ablation. During electrophysiology study, atrial rate was 84 beats per minute. Ventricular rate was 156 beats per minute. There were Wenckebach physiology and double firing of AV nodal fast and slow pathways. Slight change in QRS morphologies was seen depending on His-His intervals. His-ventricular intervals were constant at 50 ms. Several cases of double firing or nonreentrant AV nodal tachycardia have been reported,1–16 including a case of tachycardia-induced cardiomyopathy.11 However, our case is unique due to its presentation as a wide complex tachycardia and variable QRS morphologies secondary to possible gap physiology. We acknowledge that this impression is hypothetical but very likely due to the consistent relationship between variability in coupling intervals and QRS morphologies. The patient's remarkable clinical response after ablation strongly supports that her CHF and LV dysfunction were largely tachycardia induced.
No takes yet. Share an insight, caveat, or question.
LI et al. (2011) conducted a case report in Wide complex tachycardia and congestive heart failure (n=1). Slow-pathway ablation was evaluated. Slow-pathway ablation successfully eliminated the tachycardia caused by double firing of dual-AV nodal pathways, resolving congestive heart failure symptoms and improving left ventricular ejection fraction.