Key result
On-pump beating-heart coronary artery bypass grafting, alone or combined with aortic valve replacement, resulted in satisfactory in-hospital outcomes with only 4 deaths among 207 patients.
Why the study?
Does on-pump beating-heart coronary artery bypass grafting provide satisfactory clinical outcomes in patients with coronary artery disease?
Observational (n=207)
No
Does on-pump beating-heart coronary artery bypass grafting provide satisfactory clinical outcomes in patients with coronary artery disease?
On-pump beating-heart coronary artery bypass grafting, alone or combined with aortic valve replacement, is a safe and effective alternative with satisfactory in-hospital outcomes.
OPBHC associated with high revascularization and low morbidity in this cohort; leaves open need for RCTs before wider adoption.
Purpose: In this retrospective, observational, non-randomized study, we present the results of our department in on‐pump beating‐heart coronary artery bypass grafting and we review the relevant medical literature. Methods: All data related to patients who underwent on‐pump beating‐heart coronary artery bypass grafting at our center for three consecutive years were collected. These patients were classified into two groups: isolated bypass grafts or combined with aortic valve replacement. All data related to preoperative characteristics, procedural characteristics, and clinical outcomes are presented separately for the two groups. Results: During the study period, 175 patients underwent on‐pump beating‐heart bypass grafting alone and 32 combined with aortic valve replacement. Despite higher than average Euroscore in both groups, mortality, and morbidity were satisfactory while the rate of complete revascularization was higher than previously reported for classic off-pump surgery. Conclusion: On‐pump beating heart coronary artery bypass grafting offers an excellent alternative in the surgical treatment of coronary artery disease. Patient selection is very important, and in the hands of skilled surgeons, it may prevent intraoperative complications and offer the appropriate revascularization, especially for high-risk patients.
No takes yet. Share an insight, caveat, or question.
Konstantinos Triantafillou (2023) conducted an observational in Coronary Artery Disease (n=207). On-pump beating-heart coronary artery bypass grafting (OPBHC) was evaluated on In-hospital mortality and morbidity. On-pump beating-heart coronary artery bypass grafting, alone or combined with aortic valve replacement, resulted in satisfactory in-hospital outcomes with only 4 deaths among 207 patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: