Key result
The GP5(55-98) microsphere immunoassay demonstrated 92.6% sensitivity and 92.9% specificity for detecting equine arteritis virus antibodies, correlating significantly with the standard VNT (r=0.84).
Effect estimate: r = 0.84
p-value: p=<0.0001
The developed MIA offers a rapid and economical screening test for equine arteritis virus antibodies, though it is slightly less sensitive than the standard VNT.
The development and validation of a microsphere immunoassay (MIA) to detect equine antibodies to the major structural proteins of equine arteritis virus (EAV) are described. The assay development process was based on the cloning and expression of genes for full-length individual major structural proteins (GP5 amino acids 1 to 255 [GP5(1-255)], M(1-162), and N(1-110)), as well as partial sequences of these structural proteins (GP5(1-116), GP5(75-112), GP5(55-98), M(88-162), and N(1-69)) that constituted putative antigenic regions. Purified recombinant viral proteins expressed in Escherichia coli were covalently bound to fluorescent polystyrene microspheres and analyzed with the Luminex xMap 100 instrument. Of the eight recombinant proteins, the highest concordance with the virus neutralization test (VNT) results was obtained with the partial GP5(55-98) protein. The MIA was validated by testing a total of 2,500 equine serum samples previously characterized by the VNT. With the use of an optimal median fluorescence intensity cutoff value of 992, the sensitivity and specificity of the assay were 92.6% and 92.9%, respectively. The GP5(55-98) MIA and VNT outcomes correlated significantly (r = 0.84; P < 0.0001). Although the GP5(55-98) MIA is less sensitive than the standard VNT, it has the potential to provide a rapid, convenient, and more economical test for screening equine sera for the presence of antibodies to EAV, with the VNT then being used as a confirmatory assay.
No takes yet. Share an insight, caveat, or question.
Go et al. (2007) studied Equine arteritis virus (EAV) antibodies (n=2,500). Microsphere immunoassay (MIA) using partial GP5(55-98) protein vs. Virus neutralization test (VNT) was evaluated on Correlation between GP5(55-98) MIA and VNT outcomes (r = 0.84, p=<0.0001). The GP5(55-98) microsphere immunoassay demonstrated 92.6% sensitivity and 92.9% specificity for detecting equine arteritis virus antibodies, correlating significantly with the standard VNT (r=0.84).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: