Key result
Noninvasive surveillance techniques for cardiac allograft rejection currently have poor specificity, meaning invasive endomyocardial biopsy remains the gold standard.
Why the study?
Can noninvasive surveillance techniques safely and accurately replace endomyocardial biopsy for detecting cardiac allograft rejection?
Can noninvasive surveillance techniques safely and accurately replace endomyocardial biopsy for detecting cardiac allograft rejection?
Answers are grounded in this paper and cite their sources.
Endomyocardial biopsy remains the gold standard for cardiac allograft rejection surveillance due to the poor specificity of current noninvasive techniques.
Endomyocardial biopsy has stood the test of time as a surveillance technique; however, the expense, resources required, invasive nature, and low but definite risks have motivated investigators to pursue less invasive techniques. The search for noninvasive surveillance techniques for cardiac rejection have centered on measurements of cardiac function, intragraft electrical events, peripheral proteomic markers of graft micronecrosis, immune activation, and nonimmune accompaniments of rejection. Although several investigations allude to a reasonable negative predictive value of such monitoring, the specificity of these techniques remains poor. Until well-constructed studies not only define the predictive values of noninvasive techniques but also appropriately evaluate the clinical safety of any such approach, invasive endomyocardial biopsy will remain the gold standard.
No takes yet. Share an insight, caveat, or question.
Mehra et al. (2002) conducted a review in Cardiac allograft rejection. Noninvasive monitoring techniques vs. Invasive endomyocardial biopsy was evaluated. Noninvasive surveillance techniques for cardiac allograft rejection currently have poor specificity, meaning invasive endomyocardial biopsy remains the gold standard.
Synapse has enriched 10 related papers. Consider them for comparative context: