Key result
A high level (>10 kPa) of medullary shear-wave elastography independently predicted a 40% decline in eGFR or end-stage kidney disease (adjusted OR 2.68; 95% CI 1.12-6.41).
Why the study?
This study aimed to develop an interpretable model to predict allograft deterioration in kidney transplant recipients and evaluate the predictive ability of shear-wave elastography features.
Does shear-wave elastography combined with machine learning predict allograft deterioration in kidney transplant recipients?
Cohort (n=396)
No
Does shear-wave elastography combined with machine learning predict allograft deterioration in kidney transplant recipients?
Odds Ratio: 2.68 (95% CI 1.12–6.41)
The addition of shear-wave elastography features to laboratory data in an XGBoost model significantly improves the prediction of allograft function decline in kidney transplant recipients.
May support SWE for early allograft risk stratification in transplants; leaves open need for validation and outcome trials.
Introduction: Shear-wave elastography (SWE) is a promising noninvasive technique for measuring renal fibrosis after transplantation. This study aimed to develop an interpretable model to predict allograft deterioration in kidney transplant recipients and evaluate the predictive ability of SWE features. Methods: In this prospective cohort study, we performed SWE examinations on kidney transplant recipients at Renji Hospital between October 2020 and August 2023. The primary outcome was a composite of a 40% decline in estimated glomerular filtration rate or end-stage kidney disease. A total of 396 patients with stable renal allograft function were included. Five machine learning methods were used to construct predictive models. Results: Among all participants, 69 (17.4%) individuals reached the outcome. The XGBoost model with the addition of SWE features achieved the highest predictive performance with 20 repeats of nested tenfold cross-validation AUC of 0.870 (95% CI: 0.862-0.878) in the training dataset and 0.868 (95% CI: 0.801-0.935) in the validation dataset. Patients with higher medullary or cortical tissue stiffness had worse prognoses. A high level (>10 kPa) of medullary SWE was an independent risk predictor (adjusted OR, 2.68; 95% CI, 1.12-6.41). Conclusion: The joint use of SWE parameters and laboratory data significantly improved the risk prediction performance for a faster decline in allograft function. This interpretable XGBoost model may provide a readily available system to guide patient monitoring using noninvasive methods.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2025) conducted a cohort in kidney transplant recipients (n=396). High level (>10 kPa) of medullary shear-wave elastography vs. Lower level of medullary shear-wave elastography was evaluated on composite of a 40% decline in estimated glomerular filtration rate or end-stage kidney disease (adjusted OR 2.68, 95% CI 1.12-6.41). A high level (>10 kPa) of medullary shear-wave elastography independently predicted a 40% decline in eGFR or end-stage kidney disease (adjusted OR 2.68; 95% CI 1.12-6.41).