This is the authors' abstract. We don't add key points for this paper.
Elastography is a useful noninvasive tool for the assessment of renal transplant recipients. 2D-shear wave elastography (SWE) PLUS and viscosity plane-wave ultrasound (Vi PLUS) have emerged as novel techniques that promise to offer improved renal stiffness and viscosity measures due to improved processing algorithms. Methods: We performed a cross-sectional study of 50 kidney transplanted patients (16 women, 34 men; mean age of 47.5 ± 12.5; mean estimated glomerular filtration rate (eGFR) estimated by Chronic Kidney Disease Epidemiology Collaboration formula: 52.19 ± 22.6 mL/min/1.73 m2; and a mean duration after transplant of 10.09 ± 5 years). For every patient, we obtained five valid measurements of renal stiffness (obtained from five different frames in the cortex of the renal graft), and also tissue viscosity, with a C6-1X convex transducer using the Ultra-Fast™ software available on the Aixplorer Mach 30 ultrasound system (Supersonic Imagine, Aix-en-Provence, France). The median values of elastographic and viscosity measures have been correlated with the patients’ demographic, biological, and clinical parameters. Results: We obtained a cut-off value of renal cortical stiffness of <27.3 kiloPascal(kPa) for detection of eGFR < 60 mL/min/1.73 m2 with 80% sensitivity and 85% specificity (AUC = 0.811, p < 0.0001), a cut-off value of <26.9 kPa for detection of eGFR < 45 mL/min/1.73 m2 with 82.6% sensitivity and 74% specificity (AUC = 0.789, p < 0.0001), and a cut-off value of <23 kPa for detection of eGFR < 30 mL/min/1.73 m2 with 88.8% sensitivity and 75.6% specificity (AUC = 0.852, p < 0.0001). We found a positive correlation coefficient between eGFR and the median measure of renal cortical stiffness (r = 0.5699, p < 0.0001), between eGFR the median measure of viscosity (r = 0.3335, p = 0.0180), between median depth of measures and renal cortical stiffness (r = −0.2795, p = 0.0493), and between median depth of measures and body mass index (BMI) (r = 0.6574, p < 0.0001). Our study showed good intra-operator agreement for both 2D SWE PLUS measures—with an intraclass correlation coefficient (ICC) of 0.9548 and a 95% CI of 0.9315 to 0.9719—and Vi PLUS, with an ICC of 0.8323 and a 95% CI of 0.7457 to 0.8959. The multivariate regression model showed that 2D SWE PLUS values were associated with eGFR, Vi PLUS, and depth of measures. Conclusions: Assessment of renal allograft stiffness and viscosity may prove to be an effective method for identifying patients with chronic allograft injury and could prove to be a low-cost approach to provide additional diagnostic information of kidney transplanted patients.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Maralescu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: