Key result
Shear wave elastography demonstrated superior diagnostic accuracy for detecting chronic kidney disease compared to conventional ultrasound, with an AUC of 0.87 and a cut-off of ≤4.31 kPa yielding 80.3% sensitivity and 79.5% specificity.
Why the study?
Does shear wave elastography improve the detection of chronic kidney disease compared to conventional ultrasound in adults?
Cross-Sectional (n=309)
No
Does shear wave elastography improve the detection of chronic kidney disease compared to conventional ultrasound in adults?
Answers are grounded in this paper and cite their sources.
Shear wave elastography is superior to conventional ultrasound in detecting chronic kidney disease, with a Young's modulus cut-off of ≤4.31 kPa accurately identifying non-diseased kidneys.
OBJECTIVE: To investigate the use of shear wave elastography (SWE)-derived estimates of Young's modulus (YM) as an indicator to detect abnormal renal tissue diagnosed by estimated glomerular filtration rate (eGFR). METHODS: The study comprised 106 chronic kidney disease (CKD) patients and 203 control subjects. Conventional ultrasound was performed to measure the kidney length and cortical thickness. SWE imaging was performed to measure renal parenchymal stiffness. Diagnostic performance of SWE and conventional ultrasound were correlated with serum creatinine, urea levels and eGFR. RESULTS: Pearson's correlation coefficient revealed a negative correlation between YM measurements and eGFR (r = -0.576, p < 0.0001). Positive correlations between YM measurements and age (r = 0.321, p < 0.05), serum creatinine (r = 0.375, p < 0.0001) and urea (r = 0.287, p < 0.0001) were also observed. The area under the receiver operating characteristic curve for SWE (0.87) was superior to conventional ultrasound alone (0.35-0.37). The cut-off value of less or equal to 4.31 kPa suggested a non-diseased kidney (80.3% sensitivity, 79.5% specificity). CONCLUSION: SWE was superior to renal length and cortical thickness in detecting CKD. A value of 4.31 kPa or less showed good accuracy in determining whether a kidney was diseased or not. Advances in knowledge: On SWE, CKD patients show greater renal parenchymal stiffness than non-CKD patients. Determining a cut-off value between normal and diseased renal parenchyma may help in early non-invasive detection and management of CKD.
No takes yet. Share an insight, caveat, or question.
Leong et al. (2018) conducted a cross-sectional in Chronic kidney disease (n=309). Shear wave elastography (SWE) vs. Conventional ultrasound was evaluated on Area under the ROC curve (AUC) for detecting chronic kidney disease (p=<0.0001). Shear wave elastography demonstrated superior diagnostic accuracy for detecting chronic kidney disease compared to conventional ultrasound, with an AUC of 0.87 and a cut-off of ≤4.31 kPa yielding 80.3% sensitivity and 79.5% specificity.
Synapse has enriched 10 related papers. Consider them for comparative context: