Key result
In heart transplant recipients, average short-axis fractional area change (SAXFAC) was significantly lower in patients with clinically significant rejection compared to healthy transplants (32% vs. 46%, P=0.01).
Why the study?
RV allograft dysfunction occurs in half of heart transplant recipients, but non-invasive assessment of RV function during rejection is not well described.
Does short-axis fractional area change (SAXFAC) correlate with the severity of allograft rejection in heart transplant recipients?
Observational (n=37)
No
Does short-axis fractional area change (SAXFAC) correlate with the severity of allograft rejection in heart transplant recipients?
Absolute Event Rate: 32% vs 46%
p-value: p=0.01
Short-axis fractional area change (SAXFAC) is a simple echocardiographic technique that may help non-invasively identify clinically significant allograft rejection in heart transplant recipients.
SAXFAC was associated with rejection in HT recipients; hypothesis-generating and requires prospective validation before clinical adoption.
AIMS: Right ventricular (RV) allograft dysfunction is present in half of all heart transplant (HT) recipients. Non-invasive assessment of RV function in the setting of rejection is not well described. We outline an echocardiographic technique, short-axis fractional area change (SAXFAC), to evaluate RV function in the HT population and correlate this with the grade of pathologic rejection. METHODS AND RESULTS: We retrospectively reviewed the electronic medical records of 110 people who received a HT between 1 January 2015 and 29 February 2020 and had no evidence of rejection. One hundred eighty-two transthoracic echocardiograms (TTEs) completed up to 1 year from the date of transplantation were analysed for the target acoustic window, the parasternal mid-ventricular short-axis view. Sixty-one TTEs from 23 healthy transplants were deemed appropriate for SAXFAC determination. Thirty-three organ recipients with at least grade 1R allograft rejection were also identified, and their TTEs screened for SAXFAC analysis. Two expert readers independently calculated SAXFAC as follows: RV end-diastolic area minus end-systolic area divided by end-diastolic area. Using commercially available software (Epsilon, Ann Arbor, Michigan), we quantified RV radial strain, longitudinal strain, and apical fractional area change (FAC). Twenty-eight transplant recipients with grade 0R or 1R rejection and nine patients with clinically significant rejection completed the study analysis. SAXFAC demonstrated significant variability in the entire population with an inverse relationship to severity of allograft rejection (P ≤ 0.01). Radial strain and FAC were also associated with clinically significant rejection (P ≤ 0.01). CONCLUSIONS: Short-axis fractional area change is a simple two-dimensional technique to assess RV function in HT recipients and showed no significant inter-observer variability. In our small, single-centre, retrospective case series, lower SAXFAC values were associated with clinically significant allograft rejection. The small sample size and infrequent occurrence of rejection make our observations hypothesis-generating only. We advocate dedicated RV SAXFAC imaging planes be included when assessing allograft function.
No takes yet. Share an insight, caveat, or question.
Atzenhoefer et al. (2021) conducted an observational in Heart transplant recipients (n=37). Clinically significant allograft rejection vs. Healthy transplants (grade 0R or 1R rejection) was evaluated on Average short-axis fractional area change (SAXFAC) (p=0.01). In heart transplant recipients, average short-axis fractional area change (SAXFAC) was significantly lower in patients with clinically significant rejection compared to healthy transplants (32% vs. 46%, P=0.01).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: