Key result
Acute pulmonary arterial occlusion in fetal lambs doubled myocardial blood flow to all regions of the heart (e.g., RV flow increased from 266 to 504 ml/min/100 g), showing preserved flow reserve.
In a fetal sheep model, the right ventricle's sensitivity to acute pressure loading is not caused by a limitation in myocardial blood flow, demonstrating significant fetal myocardial flow reserve.
Answers are grounded in this paper and cite their sources.
Findings in fetal lambs indicate preserved myocardial flow reserve during acute RV pressure load; leaves open translation to human fetal cardiology.
BACKGROUND: It has previously been shown that the fetal right ventricle (RV) is sensitive to changes in arterial pressure and that its stroke volume is significantly reduced with acute increases in pulmonary arterial pressure. However, the myocardial blood flow (MBF) response to increases in pulmonary arterial pressure have not been investigated in the fetus. METHODS AND RESULTS: To assess whether the RV afterload sensitivity to arterial pressure is associated with limitation in MBF, seven fetal lambs were instrumented at 130 days of gestation with a pulmonary arterial occluder and intravascular catheters. RV stroke volume was measured by an electromagnetic flow probe and MBF by 15-microns labeled microspheres. MBF was determined at baseline and during incremental increases in pulmonary arterial pressure. Maximal MBF was determined in seven additional fetuses during adenosine infusion. The highest tolerated pressure was associated with a 50% reduction in RV stroke volume. The highest pulmonary arterial occlusion pressure resulted in a doubling of MBF to all regions of the heart (266 +/- 99 to 504 +/- 158, 193 +/- 69 to 387 +/- 100, and 171 +/- 66 to 338 +/- 134 ml/min/100 g for the RV, septum, and left ventricle, respectively). The best correlation for increases in both RV and global MBF was the RV heart rate-systolic pulmonary pressure product. Adenosine infusion was associated with a threefold increase in global MBF that was significantly greater than the MBF achieved during pulmonary arterial occlusion. CONCLUSIONS: The fetal RV sensitivity to acute pressure loading is not associated with limitation of MBF. The fetal myocardium has a remarkable flow reserve that allows for preservation of function during acute increases in arterial pressure.
No takes yet. Share an insight, caveat, or question.
Reller et al. (1992) studied Severe right ventricular pressure loading (n=14). Acute pulmonary arterial occlusion vs. Baseline was evaluated on Myocardial blood flow (MBF). Acute pulmonary arterial occlusion in fetal lambs doubled myocardial blood flow to all regions of the heart (e.g., RV flow increased from 266 to 504 ml/min/100 g), showing preserved flow reserve.
Synapse has enriched 10 related papers. Consider them for comparative context: