Why the study?
Neurointerventionalists require in-vitro models to train for worst-case scenarios and test devices under FDA-recommended navigation criteria, motivating the development of a compliant benchmarking model.
The development of a patient-specific in-vitro vascular model complying with FDA recommendations provides a standardized, clinically relevant approach for neurovascular device testing.
May facilitate standardized neurovascular device testing in complex anatomies; leaves open clinical translation and outcome validation.
BackgroundNeurointerventionalists use in-vitro vascular models to train for worst-case scenarios and test new devices in a simulated use environment to predict clinical performance. According to the Food and Drug Administration (FDA), any neurovascular navigation device should be able to successfully navigate two 360-degree turns and two 180-degree turns at the distal portion of the anatomical model. Here, we present a device benchmarking vascular model that complies with FDA recommendations.MethodsOur vascular model was assembled from quantitative characterization of 49 patients who underwent CT angiography either for acute ischemic stroke caused by large vessel occlusion or for aneurysm treatment. Following complete characterization of these data, the vascular segments were 3D reconstructed from CT angiograms of 6 selected patients that presented with challenging anatomy. The curvature and total rotational angle were calculated for each segment and the anatomical parts that complied with FDA recommendations were fused together into a single in-vitro model.ResultsThe model was constructed containing two common carotid branches arising from a type two aortic arch and the dimensions of the overall model exceeded the recommendations of the FDA. Two experienced neurointerventionalists tested the model for navigation difficulty using several devices on an in-vitro perfusion system and concluded that the model provided a realistic, challenging scenario.ConclusionsThis model provides a first prototype designed according to FDA recommendations of cumulative angle while also integrating an aggregation of actual patient-specific anatomy. The availability of this clinically relevant benchmark model presents a potential standardized approach for neurovascular device testing.
No takes yet. Share an insight, caveat, or question.
Epshtein et al. (2023) studied Acute ischemic stroke caused by large vessel occlusion or aneurysm (n=49). In-vitro vascular model based on patient vessel geometry was evaluated on Compliance with FDA recommendations and navigation difficulty.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: