Key result
Curative ablation of atrial fibrillation eliminated prolonged sinus pauses (>2 seconds) and decreased the maximum sinus pause from 4.5 seconds to 1.7 seconds in all 4 patients.
Why the study?
Does ablation (pulmonary vein isolation, superior vena cava isolation, and cavo-tricuspid isthmus ablation) reduce prolonged sinus pauses in patients with paroxysmal atrial fibrillation?
Case Report (n=4)
No
Does ablation (pulmonary vein isolation, superior vena cava isolation, and cavo-tricuspid isthmus ablation) reduce prolonged sinus pauses in patients with paroxysmal atrial fibrillation?
Curative ablation of atrial fibrillation can eliminate prolonged sinus pauses upon termination of paroxysmal AF, potentially avoiding the need for pacemaker implantation.
Answers are grounded in this paper and cite their sources.
May avoid pacing in select paroxysmal AF patients with pauses; hypothesis-generating from case series, needs prospective confirmation.
BACKGROUND: Symptomatic prolonged sinus pauses upon termination of atrial fibrillation (AF) are an indication for pacemaker implantation. METHODS AND RESULTS: We evaluated the clinical outcomes of 4 patients who showed prolonged sinus pauses (> 2 seconds) upon termination of AF and thus underwent ablation. The ablative procedure included pulmonary vein isolation, superior vena cava isolation, and cavo-tricuspid isthmus ablation. Twenty-four-hour ambulatory electro-cardiogram monitoring was performed before and 1 month after ablation. The maximum sinus pause decreased from 4.5 +/- 2.1 seconds before ablation to 1.7 +/- 0.2 seconds after ablation. Sinus pauses > 2.0 seconds disappeared after ablation in all 4 patients. Minimum heart rate increased from 35.0 +/- 8.1 beats/minute before ablation to 52 +/- 6.7 beats/minute after ablation. The number of heart beats in 24 hours did not change significantly after ablation. CONCLUSION: Prolonged sinus pauses after paroxysmal AF may result from depressed sinus node function, which can be eliminated by curative ablation of AF.
No takes yet. Share an insight, caveat, or question.
Ohkubo et al. (2007) conducted a case report in Paroxysmal atrial fibrillation with prolonged sinus pause (n=4). Curative ablation of atrial fibrillation (Pulmonary vein isolation) vs. Baseline (before ablation) was evaluated on Maximum sinus pause. Curative ablation of atrial fibrillation eliminated prolonged sinus pauses (>2 seconds) and decreased the maximum sinus pause from 4.5 seconds to 1.7 seconds in all 4 patients.
Synapse has enriched 10 related papers. Consider them for comparative context: