Key result
Delayed right ventricular wall perforation by a pacemaker lead occurred 3 months post-implantation in an 82-year-old female patient and was successfully managed conservatively.
Why the study?
Cardiac perforation by a permanent pacemaker lead is a critical complication that typically occurs within 24 hours but can present late.
Demonstrates that delayed right ventricular perforation by a pacemaker lead can occur months after implantation and may be managed conservatively.
Answers are grounded in this paper and cite their sources.
May support conservative management in select delayed RV perforations; leaves open broader applicability and safety confirmation.
Cardiac perforation by the lead of permanent pacemaker implantation devices is a critical complication that often occurs within 24 h after the implantation but can occur later. Here, we report a case of an 82-year-old female patient with perforation of the right ventricular wall due to right ventricle lead after 3 months of pacemaker implantation, which was managed conservatively.
No takes yet. Share an insight, caveat, or question.
Munde et al. (2024) studied this question. Delayed right ventricular wall perforation by a pacemaker lead occurred 3 months post-implantation in an 82-year-old female patient and was successfully managed conservatively.