Why the study?
Subacute myocardial perforation from pacemaker and implantable cardioverter-defibrillator leads is rare, affecting 0.5%-1.2% of patients, but remains a potentially life-threatening complication.
Subacute myocardial perforation is a rare but potentially life-threatening complication of active fixation pacemaker leads that can present as device failure and requires prompt imaging and surgical management.
Answers are grounded in this paper and cite their sources.
Device failure after pacemaker implantation warrants urgent perforation imaging; single case leaves open true incidence with active fixation leads.
Myocardial perforation is an uncommon but potentially life-threatening complication of pacemaker and implantable cardioverter-defibrillator. Myocardial perforation may be acute, subacute or chronic when it occurs within 24 hours of the device insertion; between 1 day and 30 days; and more than 30 days after implantation. This complication may occur in 1.7%-7% of patients. However, subacute myocardial perforation is rare and affects 0.5%-1.2% of patients. We report the case of an 85-year-old patient with a pacemaker failure 10 days after implantation due to a subacute myocardial perforation caused by an active fixation ventricular lead. Transthoracic echocardiography showed penetration of the ventricular lead through the right ventricular apex into the pericardium without any pericardial effusion. We confirmed myocardial perforation by a CT scan. We referred her to the surgery ward where she was successfully managed.