Why the study?
Does continuous ambulatory peritoneal dialysis significantly alter the clearance of quinidine in a patient?
Does continuous ambulatory peritoneal dialysis significantly alter the clearance of quinidine in a patient?
Quinidine dosage adjustment is likely unnecessary for patients undergoing continuous ambulatory peritoneal dialysis, as dialysis clearance accounts for a negligible fraction of total body clearance.
Answers are grounded in this paper and cite their sources.
Minimal quinidine removal by peritoneal dialysis in this case; leaves open dosing implications for broader CAPD populations.
The clearance of quinidine was evaluated in a patient undergoing continuous ambulatory peritoneal dialysis (CAPD). The dialysis clearance of quinidine was 0.793 ml/min which represented only 0.61% of the total body clearance (154.21 ml/min) of the drug. The elimination half-life of quinidine was 5.44 hours. Based on our results, dosage adjustment of quinidine does not appear to be necessary for patients undergoing CAPD.
No takes yet. Share an insight, caveat, or question.
Chin et al. (1981) studied this question.