Key result
Preoperative AI-ECG Grade 3 diastolic function is linked to ~145% higher late mortality after SAVR.
Why the study?
Diastolic dysfunction is common in aortic stenosis and may affect surgical aortic valve replacement outcomes, motivating evaluation of preoperative AI-generated diastolic function grades and their postoperative progression.
Does AI ECG-derived diastolic function grade predict early and late mortality in patients undergoing surgical aortic valve replacement?
Cohort (n=5,503)
Does AI ECG-derived diastolic function grade predict early and late mortality in patients undergoing surgical aortic valve replacement?
Hazard Ratio: 2.45
p-value: p=<0.001
AI ECG-derived diastolic function grading provides a powerful, noninvasive tool that strongly predicts early complications and long-term mortality in patients undergoing surgical aortic valve replacement.
Background Diastolic dysfunction is common in patients with aortic stenosis and may influence outcomes following surgical aortic valve replacement. We aimed to examine the association of preoperative artificial intelligence (AI)‐generated diastolic function grades with early and late outcomes following aortic valve replacement and how postoperative progression influence prognosis. Methods We identified 5503 patients undergoing aortic valve replacement between 2000 and 2023. Diastolic function was assessed using a validated deep‐learning AI model applied to 12‐lead ECGs done preoperatively and on postoperative follow‐up. Diastolic grades were classified by AI into Grades 1 to 3. Longitudinal trend analyses and multivariable regression models were used to assess study end points. Results Among 5503 patients (mean age 72.4±10.8 years; 39% female), higher AI ECG diastolic grades were associated with greater comorbidity burden, including diabetes, renal disease, and heart failure. AI ECG diastolic Grade 3 was independently associated with higher in‐hospital mortality (odds ratio, 2.5; P =0.007) and other complications. At 5‐year follow‐up, patients with Grade 3 showed the least improvement in diastolic function by both ECG and echocardiography. Grades 2 and 3 diastolic function at baseline were independently associated with increased late mortality (hazard ratio, 1.3 and 2.45, respectively; both P <0.001). Additionally, lack of improvement in AI ECG diastolic grade by 1 year was also independently associated with late mortality. Conclusions AI ECG–derived diastolic function grades strongly correlates with early complications and long‐term mortality and diastolic progression after aortic valve replacement. AI ECG provides a powerful, noninvasive tool for risk stratification and longitudinal monitoring of patients with aortic stenosis.
No takes yet. Share an insight, caveat, or question.
Sawma et al. (2026) conducted a cohort in aortic stenosis (n=5,503). Preoperative AI ECG-derived diastolic function Grade 3 vs. Lower AI ECG diastolic grades was evaluated on Late mortality (HR 2.45, p=<0.001). Preoperative AI ECG-derived Grade 3 diastolic function was independently associated with increased late mortality after surgical aortic valve replacement (HR 2.45; P<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: