Key result
Balloon size in balloon atrial septostomy showed no significant difference in post-procedural ASD size or systemic oxygen saturation in d-TGA.
Why the study?
Does the size of the septostomy balloon (1.8 mL vs 4 mL) affect post-procedural atrial septal defect size, systemic oxygen saturation, or prostaglandin E1 requirement in neonates with simple d-TGA undergoing balloon atrial septostomy?
Does the size of the septostomy balloon (1.8 mL vs 4 mL) affect post-procedural atrial septal defect size, systemic oxygen saturation, or prostaglandin E1 requirement in neonates with simple d-TGA undergoing balloon atrial septostomy?
Answers are grounded in this paper and cite their sources.
Although retrospective data suggest small (1.8 mL) and large (4 mL) septostomy balloons achieve similar ASD sizes and oxygen saturations in neonates with d-TGA, multiple balloon sizes should remain available on the shelf until prospective studies confirm these findings, especially for premature and small-for-gestational-age neonates.
Balloon atrial septostomy (BAS) was first performed by Rashkind and Miller in 1966 as a lifesaving procedure in a neonate with severe oxygen desaturation born with dextro–transposition of the great arteries (d-TGA).1 This procedure remains one of the rare indications for emergent cardiac catheterization in neonates and has a class I indication in patients with d-TGA with restricted atrial communication as means to enhance atrial level mixing of oxygenated and deoxygenated blood in parallel circuits.
No takes yet. Share an insight, caveat, or question.
Iman Naimi (2022) conducted an editorial in Simple dextro-transposition of the great arteries (d-TGA) (n=134). Small septostomy balloon (Fogarty balloon, 1.8 mL maximum inflation volume, 15 mm diameter) vs. Large septostomy balloon (Miller balloon, 4 mL maximum inflation volume, 19 mm diameter) was evaluated on Post-BAS atrial septal defect (ASD) size and systemic oxygen saturation (p=0.22 for post-BAS ASD size; 0.83 for post-BAS systemic oxygen saturation). Balloon size in balloon atrial septostomy showed no significant difference in post-procedural ASD size or systemic oxygen saturation in d-TGA.
Synapse has enriched 10 related papers. Consider them for comparative context: