Answers are grounded in this paper and cite their sources.
The radiation absorbed dose to very low birth weight infants from 18F-fluorodeoxyglucose was investigated. Ten newborns undergoing clinical positron tomography lung imaging were included in this study. Two consecutive 45-min dynamic scans immediately following intravenous injection of fluorodeoxyglucose were acquired; the first was over the head, and the second was over the chest. Time-activity curves were generated for the brain, heart wall, lungs, and, when visible, the kidneys. The cumulated activity measurements obtained were for the entire organ masses; these masses were much smaller than the corresponding organ masses for the newborn mathematical model. Patient-specific dosimetry yielded average doses of 2.5 x 10(-1) mGy MBq(-1) for the brain, 6.8 x 10(-1) mGy MBq(-1) for the heart wall, 2.2 x 10(-1) mGy MBq(-1) for the kidneys, and 4.4 x 10(-1) mGy MBq(-1) for the lungs. The effective dose was estimated to be 2.1 x 10(-1) mSv MBq(-1), which is half that previously published for newborns but still an order of magnitude higher than that for adults.
No takes yet. Share an insight, caveat, or question.
Niven et al. (2003) studied this question.