Answers are grounded in this paper and cite their sources.
Light from coronas at tungsten point electrodes in a number of insulating liquids has been photographed and the dimensions of the luminous region measured. It was found that the radius of curvature of the tip of the corona region was proportional to the applied voltage. The ratio of the change in the applied voltage to the change in the corona radius which resulted is taken to be a measure of the local electric field at the boundary of the corona region. The effects of viscosity on the corona in hexachlorodiphenyl are also reported.
No takes yet. Share an insight, caveat, or question.
Shammas et al. (1974) studied this question.