Key result
Sutureless implantation of the Perceval S aortic valve bioprosthesis via ministernotomy was successfully deployed in all patients, with a 30-day mortality of 1.4%.
Why the study?
Is minimally invasive aortic valve replacement with the sutureless Perceval S bioprosthesis safe and effective in patients with isolated aortic valve stenosis?
Cohort (n=72)
Is minimally invasive aortic valve replacement with the sutureless Perceval S bioprosthesis safe and effective in patients with isolated aortic valve stenosis?
Answers are grounded in this paper and cite their sources.
Sutureless implantation of the Perceval S bioprosthesis via ministernotomy is a feasible and reproducible alternative for aortic valve replacement, offering reduced cross-clamp times and good short-term hemodynamics.
AIM: Although minimally invasive aortic valve replacement (MIAVR) has been shown to cause less morbidity than conventional surgery, it has not yet received broad application. The purpose of this study was to evaluate sutureless implantation using the Perceval S aortic valve bioprosthesis (Sorin Group, Saluggia, Italy) via ministernotomy. METHODS: Seventy-two patients (43 women, 29 men; mean age 77.4 ± 5.3 years) with isolated aortic valve stenosis (mean gradient of 52 ± 14 mmHg) underwent aortic valve implantation with the sutureless Perceval S bioprosthesis, following cardiopulmonary bypass (CPB), aortic cross-clamping (ACC), cardioplegic arrest and removal of the calcified native valve. The mean logistic EuroSCORE was 9.7 ± 6.2%. RESULTS: The prosthetic valve was successfully deployed in all patients. Thirty-day mortality was 1.4% (n = 1). Mean CBP, ACC, and implantation times were 68 ± 18, 40 ± 13 and 8.9 ± 4 min, respectively. Perioperative echocardiography revealed significant paravalvular leakage in one patient. Postoperative mean gradient was 11.6 ± 5.1 mmHg. At a mean follow-up of 13 ± 6.7 months, no significant paravalvular leakage or valvular regurgitation was observed, and no migration or dislodgement of the prosthesis occurred. CONCLUSION: This study shows that sutureless implantation of the Perceval S aortic valve bioprosthesis provides a simple and reproducible alternative for MIAVR. As the valve does not need to be sutured, it may also result in reduced ACC and CPB times. This self-anchoring valve may also allow the application of MIAVR to a broader spectrum of patients. This new technology needs a long-term follow-up.
No takes yet. Share an insight, caveat, or question.
Santarpino et al. (2013) conducted a cohort in Isolated aortic valve stenosis (n=72). Sutureless implantation using the Perceval S aortic valve bioprosthesis via ministernotomy was evaluated on 30-day mortality. Sutureless implantation of the Perceval S aortic valve bioprosthesis via ministernotomy was successfully deployed in all patients, with a 30-day mortality of 1.4%.
Synapse has enriched 10 related papers. Consider them for comparative context: