The use of an acceleration rate response pacemaker with a steroid-eluting screw-in lead successfully restored normal activity levels in a dog with third-degree AV block over a 19-month follow-up.
Answers are grounded in this paper and cite their sources.
May support rate-responsive pacing in canine AV block; leaves open generalizability without larger controlled studies.
Permanent pacemakers are commonly used in veterinary practice and can have a dramatic effect on the treatment of heart block. A Labrador Retriever dog suffering from exercise intolerance secondary to third degree atrioventricular block was treated with a new pacemaker system. A steroid-eluting screw-in type lead that has the advantage of being more fixed to the myocardial wall without increasing the pacing threshold was used. The heart rate was regulated with an acceleration sensing pacemaker generator that included several automatic modulation systems. Nineteen months after implantation, the dog has a normal level of activity. The present case suggests that this pacemaker design may offer important advantages for canine patients.