Key result
Three-dimensional ultrasound and MRI showed good qualitative agreement for carotid artery haemodynamic parameters with comparable root mean square errors.
Why the study?
Does 3D ultrasound provide comparable haemodynamic wall parameter estimates to MRI when combined with computational fluid dynamics in carotid arteries?
Observational (n=9)
Does 3D ultrasound provide comparable haemodynamic wall parameter estimates to MRI when combined with computational fluid dynamics in carotid arteries?
3D ultrasound combined with computational fluid dynamics provides comparable hemodynamic parameter estimates to MRI in superficial arteries, offering a potentially more cost-effective alternative.
Answers are grounded in this paper and cite their sources.
3D ultrasound may offer a feasible alternative for carotid hemodynamics; leaves open prospective validation before clinical adoption.
Atherosclerosis is a major cause of morbidity and mortality. Its apparent link with wall shear stress (WSS) has led to considerable interest in the in vivo estimation of WSS. Determining WSS by combining medical images with computational fluid dynamics (CFD) simulations can be performed both with magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). This study compares predicted 3D flow patterns based on black blood MRI and 3DUS. Velocity fields in the carotid arteries of nine subjects have been reconstructed, and the haemodynamic wall parameters WSS, oscillatory shear index (OSI), WSS gradients (WSSG) and angle gradients (WSSAG) were compared between the two imaging techniques. There was a good qualitative agreement between results derived from MRI and 3DUS (average correlation strength above 0.60). The root mean square error between haemodynamic wall parameters was comparable to the range of the expected variability of each imaging technique (WSS: 0.411 N m(-2); OSI: 0.048; temporal WSSG: 150 N s(-1) m(-2); spatial WSSG: 2.29 N m(-3); WSSAG: 87.6 rad m(-1)). In conclusion, MRI and 3DUS are capable of providing haemodynamic parameters when combined with CFD, and the predictions are in most cases qualitatively and quantitatively similar. The relatively high cost of MRI and continuing improvement in ultrasound favour US to MRI for future haemodynamic studies of superficial arteries.
No takes yet. Share an insight, caveat, or question.
Glor et al. (2004) reported an observational. Three-dimensional ultrasound (3DUS) vs. Magnetic resonance imaging (MRI) was evaluated on Haemodynamic wall parameters (WSS, OSI, WSSG, WSSAG) (average correlation strength >0.60). Three-dimensional ultrasound and MRI showed good qualitative agreement for carotid artery haemodynamic parameters with comparable root mean square errors.