Key result
An intracardiac right ventricular microaxial pump was safely and effectively applied during beating heart coronary surgery in 6 patients, maintaining cardiac output at 87% of baseline.
Why the study?
Does an intracardiac right ventricular microaxial pump safely maintain hemodynamics in patients undergoing beating heart coronary surgery?
Does an intracardiac right ventricular microaxial pump safely maintain hemodynamics in patients undergoing beating heart coronary surgery?
An intracardiac right ventricular microaxial pump can be safely and effectively used to maintain hemodynamics during beating heart coronary surgery.
Answers are grounded in this paper and cite their sources.
Initial case series suggests hemodynamic support is feasible; leaves open efficacy and safety in randomized settings.
To evaluate the safety and efficacy of a new developed intracardiac right ventricular microaxial pump (elect 300, Impella AG, Aachen) the intracardiac pump (IRVP) was applied to patients undergoing beating heart coronary surgery. To our knowledge, this is the first description of an intracardiac microaxial pump device inserted through the pulmonary artery into the right ventricle. Six patients undergoing coronary surgery for 3-vessel disease were operated on without extracorporeal circulation with the new IRVP device. During the procedure, cardiac output (CO), arterial blood pressure (MAP), central venous pressure (CVP), right ventricular pressure (RVP), pulmonary artery pressure (PAP) and left atrial pressure (LAP) were recorded. Placement of the IRVP was easy, quick and without significant blood loss. During the procedure, all devices worked well. Rhythm disturbances requiring therapeutic measures were not observed. Patients with beating heart surgery and IRVP support maintained CO (87 (73-116) % of baseline) and MAP (101 (69-126) % of baseline). After the Trendelenburg maneuver, CVP raised and RVP remained constant. PAP (150 (117-164) % of baseline) and LAP (290 (75-400) % of baseline) raised, indicating an effective blood transport out of the RV. Our results show that an IRVP can be applied safely and effectively in patients undergoing beating heart coronary surgery.
No takes yet. Share an insight, caveat, or question.
Andreas Boening (2004) studied 3-vessel coronary disease (n=6). Intracardiac right ventricular microaxial pump (IRVP) was evaluated on Safety and efficacy (hemodynamic parameters including cardiac output and arterial blood pressure). An intracardiac right ventricular microaxial pump was safely and effectively applied during beating heart coronary surgery in 6 patients, maintaining cardiac output at 87% of baseline.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: