Key result
Stent implantation for coarctation of the aorta in four adult patients reduced the mean pressure gradient from 22 mmHg to 7 mmHg and increased the mean vessel diameter from 8 mm to 18 mm.
Why the study?
Does stent implantation reduce pressure gradients and improve aortic diameter in adult patients with coarctation of the aorta?
Case Report (n=4)
No
Does stent implantation reduce pressure gradients and improve aortic diameter in adult patients with coarctation of the aorta?
Absolute Event Rate: 7% vs 22%
Stent implantation is a feasible and effective nonsurgical treatment option for adult patients with coarctation of the aorta, significantly reducing pressure gradients and increasing aortic diameter.
Supports feasibility in adult coarctation; hypothesis-generating and should not yet change practice.
INTRODUCTION: Coarctation of the aorta (CoA) accounts for 5%-8% of all congenital heart defects. If left untreated, most patients with significant CoA will have varying degrees of morbidity (e.g. hypertension, stroke, collateral formation and ventricular hypertrophy), possibly even mortality. Traditionally, treatment for this condition is surgical. Herein, we report stenting during catheterisation as an alternative nonsurgical treatment option for patients with CoA, and present the treatment outcomes of patients who underwent this treatment option. METHODS: We retrospectively reviewed four patients (2 men and 2 women; age range 20-41 years) who underwent CoA stenting under general anaesthesia for the treatment of native CoA or restenosis of CoA at our institution. Three patients had a 40-mm Palmaz stent inserted, while one had a 39-mm Cheatham-Platinum covered stent inserted. Angiography and measurement of pressure gradients were performed before and after stent implantation to ensure good treatment outcomes. RESULTS: The patients' treatment outcomes were good, with a significant reduction in pressure gradients across the narrowed segments. Angiography showed relief of CoA. The patients were followed up for 1-3 years, during which no complications were noted. CONCLUSION: This is the first reported series in Singapore on the nonsurgical treatment of CoAs in adult patients using stents during interventional cardiac catheterisation. This less invasive procedure may lead to a new paradigm shift with regard to the treatment of CoA.
No takes yet. Share an insight, caveat, or question.
Ang et al. (2014) conducted a case report in Coarctation of the aorta (n=4). Stent implantation vs. Pre-stenting baseline was evaluated on Mean pressure gradient across the coarctation (mmHg). Stent implantation for coarctation of the aorta in four adult patients reduced the mean pressure gradient from 22 mmHg to 7 mmHg and increased the mean vessel diameter from 8 mm to 18 mm.