Key result
Biodegradable polymer drug-eluting stents had similar rates of definite/probable stent thrombosis compared with durable polymer stents (RR 0.83; 95% CI 0.62-1.11; P=0.22).
Why the study?
Does biodegradable polymer DES reduce stent thrombosis or improve clinical outcomes compared to durable polymer DES in patients with coronary artery disease?
Meta-Analysis (n=17,068)
Does biodegradable polymer DES reduce stent thrombosis or improve clinical outcomes compared to durable polymer DES in patients with coronary artery disease?
Relative Risk: 0.83 (95% CI 0.62–1.11)
p-value: p=0.22
Biodegradable polymer DES demonstrate similar safety and efficacy to durable polymer DES in patients with coronary artery disease over a mean follow-up of nearly 2 years.
Supports interchangeable stent selection; confirms comparable thrombosis safety versus durable polymer DES.
Background Drug eluting stents (DESs) made with biodegradable polymer have been developed in an attempt to improve clinical outcomes. However, the impact of biodegradable polymers on clinical events and stent thrombosis (ST) remains controversial. Methods We searched Medline, the Cochrane Library and other internet sources, without language or date restrictions for articles comparing clinical outcomes between biodegradable polymer DES and durable polymer DES. Safety endpoints were ST (definite, definite/probable), mortality, and myocardial infarction (MI). Efficacy endpoints were major adverse cardiac event (MACE) and target lesion revascularization (TLR). Results We identified 15 randomized controlled trials (n=17 068) with a weighted mean follow-up of 20.6 months. There was no statistical difference in the incidence of definite/probable ST between durable polymer- and biodegradable polymer-DES; relative risk (RR) 0.83; 95% confidence interval (CI) 0.62–1.11; P=0.22. Biodegradable polymer DES had similar rates of definite ST (RR 0.94, 95% CI 0.66–1.33, P=0.72), mortality (RR 0.94, 95% CI 0.82–1.09, P=0.43), MI (RR 1.08, 95% CI 0.92–1.26. P=0.35), MACE (RR 0.99, 95% CI 0.91–1.09, P=0.85), and TLR (RR, 0.94, 95% CI 0.83–1.06, P=0.30) compared with durable polymer DES. Based on the stratified analysis of the included trials, the treatment effect on definite ST was different at different follow-up times: ≤1 year favoring durable polymer DES and >1 year favoring biodegradable polymer DES. Conclusions Biodegradable polymer DES has similar safety and efficacy for treating patients with coronary artery disease compared with durable polymer DES. Further data with longer term follow-up are warranted to confirm the potential benefits of biodegradable polymer DES.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2014) conducted a meta-analysis in coronary artery disease (n=17,068). Biodegradable polymer drug-eluting stents vs. Durable polymer drug-eluting stents was evaluated on definite/probable stent thrombosis (ST) (RR 0.83, 95% CI 0.62-1.11, p=0.22). Biodegradable polymer drug-eluting stents had similar rates of definite/probable stent thrombosis compared with durable polymer stents (RR 0.83; 95% CI 0.62-1.11; P=0.22).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: