Answers are grounded in this paper and cite their sources.
The D.H.S.S. is supporting research in several centres to determine the feasibility of establishing a nationwide Breast Cancer Screening Programme. This paper answers the questions "What is the radiation dose produced by mammography, and is it safe?". In the context of well-women screening surveys a maximum skin dose of 2 R has been recommended. The variation of dose across the breast surface is recorded and the reasons for this enumerated. The lowest mean dose recorded with industrial quality film was 4-9 R, so that such fine-grain film cannot be used for this purpose. Doses within the recommended safety limit are achieved by the use of vacuum-packed film-screen combinations. The new rare-earth phosphor screens produce the lowest dose (0-2 R). There was no significant gonad dose. It is concluded that mammographic examination of well-women can be performed at safe radiation levels.
No takes yet. Share an insight, caveat, or question.
Asbury et al. (1975) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: