Key result
MR angiography detected significant coronary artery stenoses with 83% sensitivity and 94% specificity compared to conventional contrast angiography.
Why the study?
Does three-dimensional MR angiography accurately detect significant proximal coronary artery stenosis compared to conventional contrast angiography in patients with coronary artery disease?
Observational (n=35)
Does three-dimensional MR angiography accurately detect significant proximal coronary artery stenosis compared to conventional contrast angiography in patients with coronary artery disease?
Three-dimensional MR angiography provides high diagnostic accuracy for detecting significant proximal coronary artery stenoses compared to conventional angiography.
Answers are grounded in this paper and cite their sources.
Supports noninvasive proximal stenosis detection; leaves open need for prospective validation before clinical adoption.
The purpose of this study was to compare the diagnostic value of MR angiography (MRA) with conventional contrast angiography in coronary artery disease. Thirty-five patients underwent MRA and coronary angiography within 4 hours. Of these, three patients were investigated twice: once before and once after balloon angioplasty. The pulse sequence was a cardiac-triggered, single-slab, three-dimensional gradient-echo sequence, employing a spin-echo navigator echo measurement to track the variation of the diaphragm during the scan. The following segments of the coronary arteries were included in this prospective study: left main coronary artery, proximal and middle left anterior descending, proximal and middle left circumflex, proximal and middle right coronary artery, and intermediate branch, if present. In total, 176 segments were classified as normal or having a stenosis of less than 50% and as having a stenosis of more than 50%. Five patients were excluded because of lack of cooperation. Over all, 45 of 54 stenoses were detected and interpretable by MRA. Sensitivity, specificity, and positive and negative predictive values of MRA for detecting significant stenoses were 83%, 94%, 87%, and 93%, respectively. MRA identified significant stenoses within the major coronary arteries with a high degree of accuracy. Sensitivity and specificity are higher compared with exercise tests or scintigraphy or top of the precise localization.
No takes yet. Share an insight, caveat, or question.
Fleisch et al. (1997) conducted an observational in Coronary artery disease (n=35). MR angiography (MRA) vs. Conventional contrast angiography was evaluated on Detection of significant stenoses (>50%) (Sensitivity 83%, Specificity 94%). MR angiography detected significant coronary artery stenoses with 83% sensitivity and 94% specificity compared to conventional contrast angiography.
Synapse has enriched 10 related papers. Consider them for comparative context: