Answers are grounded in this paper and cite their sources.
Spiral-wound heat exchangers (SWHEs) exhibit high heat transfer efficiency, high-pressure resistance, and excellent thermal compensation capabilities. However, owing to the complex structure on shell-side SWHEs, it is challenging to determine precise structural design and structural optimization. In the present study, numerical simulation was employed to achieve the flow and temperature distributions on the shell-side SWHE, and the thermohydraulic mechanisms were analyzed. The effects of the spiral tube outer diameter, tube bundle radial interlayer spacing, spiral tube winding angle, and axial spacing between the tubes on the SWHE performance were investigated. The results indicate that both the temperature and velocity distributions of the shell-side fluid in the SWHEs exhibit non-uniform characteristics. Meanwhile, the heat transfer coefficient on the shell-side SWHE increased with the spiral tube outer diameter, whereas the pressure drop was rarely affected by the outer diameter. Furthermore, increasing the tube bundle radial interlayer spacing and axial spacing between pipes in the same layer simultaneously reduces the shell-side heat transfer coefficient and pressure drop. As the winding angle increased, the shell-side heat transfer coefficient increased to a peak value and then declined, whereas the pressure loss showed a linearly decreasing trend.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: