Key result
Applying both 3D connectivity and partial volume fat correction to the fully-automated iterative threshold-seeking algorithm improved test-retest precision error from 4.99% to 2.21%.
Why the study?
Inter- and intramuscular fat promotes inflammation, but the lack of reproducible MRI tools prevents measuring change and tracking intervention success.
Does a fully-automated iterative threshold-seeking algorithm improve the precision and reliability of inter- and intra-muscular fat segmentation from MRI compared to semi-automated methods?
Does a fully-automated iterative threshold-seeking algorithm improve the precision and reliability of inter- and intra-muscular fat segmentation from MRI compared to semi-automated methods?
Answers are grounded in this paper and cite their sources.
The fully-automated ITSA algorithm provides a highly precise and reliable open-source method for segmenting inter- and intra-muscular fat from MRI, facilitating its use in clinical trials.
Background INTER- and INTRAmuscular fat (IMF) is elevated in high metabolic states and can promote inflammation. While magnetic resonance imaging (MRI) excels in depicting IMF, the lack of reproducible tools prevents the ability to measure change and track intervention success. Methods We detail an open-source fully-automated iterative threshold-seeking algorithm (ITSA) for segmenting IMF from T1-weighted MRI of the calf and thigh within three cohorts (CaMos Hamilton ( N = 54), AMBERS ( N = 280), OAI ( N = 105)) selecting adults 45–85 years of age. Within the CaMos Hamilton cohort, same-day and 1-year repeated images ( N = 38) were used to evaluate short- and long-term precision error with root mean square coefficients of variation; and to validate against semi-automated segmentation methods using linear regression. The effect of algorithmic improvements to fat ascertainment using 3D connectivity and partial volume correction rules on analytical precision was investigated. Robustness and versatility of the algorithm was demonstrated by application to different MR sequences/magnetic strength and to calf versus thigh scans. Results Among 439 adults (319 female(89%), age: 71.6 ± 7.6 yrs, BMI: 28.06 ± 4.87 kg/m 2 , IMF%: 10.91 ± 4.57%), fully-automated ITSA performed well across MR sequences and anatomies from three cohorts. Applying both 3D connectivity and partial volume fat correction improved precision from 4.99% to 2.21% test–retest error. Validation against semi-automated methods showed R 2 from 0.92 to 0.98 with fully-automated ITSA routinely yielding more conservative computations of IMF volumes. Quality control shows 7% of cases requiring manual correction, primarily due to IMF merging with subcutaneous fat. A full workflow described methods to export tags for manual correction. Conclusions The greatest challenge in segmenting IMF from MRI is in selecting a dynamic threshold that consistently performs across repeated imaging. Fully-automated ITSA achieved this, demonstrated low short- and long-term precision error, conducive of use within RCTs.
No takes yet. Share an insight, caveat, or question.
Tam et al. (2024) studied Muscle adiposity (n=439). Fully-automated iterative threshold-seeking algorithm (ITSA) with 3D connectivity and partial volume correction vs. ITSA without 3D connectivity and partial volume correction was evaluated on Test-retest precision error (RMSCV). Applying both 3D connectivity and partial volume fat correction to the fully-automated iterative threshold-seeking algorithm improved test-retest precision error from 4.99% to 2.21%.
Synapse has enriched 10 related papers. Consider them for comparative context: