Case Report (n=1)
No
Periprocedural transesophageal echocardiography is crucial for diagnosing ablation catheter entrapment and guiding surgical removal to prevent mitral valve damage.
Answers are grounded in this paper and cite their sources.
May support TEE use to avert valve injury in rare entrapments; leaves open need for prospective validation.
The patient was a 66-year-old man with a history of paroxysmal supraventricular tachycardia status, post slow pathway ablation 7 years ago. Patient complained of palpitations during the last 4 years. Twelve-lead electrocardiography (ECG) showed sinus rhythm with multiple ventricular premature contractions (VPCs) (Figure 1 A), originating from left ventricular (LV) outflow tract. The 24-h Holter ECG recordings documented frequent VPCs with bigeminy, trigemini, and couplets occurring regularly throughout the day. After optimized medical treatment, symptomatic VPCs persisted and patient was hospitalized for catheter ablation. The NaviStar® Thermocool catheter for electrophysiological mapping was introduced through the right femoral artery and advanced to the aortic cusps. Evaluation of aortomitral continuity and mitral annulus was completed as part of confirming the origin of VPCs. Anatomical and activation mapping was performed. At this point in the procedure, without any prior abnormal event, the ablation catheter could no longer be maneuvered. Gentle traction and rotation maneuvers attempting to release the tip were unsuccessful. Blinded traction was immediately halted because we speculated that the catheter had become entrapped in the LV cavity. A periprocedural transesophageal echocardiogram (Figure 1B) confirmed the ablation catheter entrapment by chordae with mild mitral regurgitation. Emergent surgery was performed. The left atrium (LA) was opened. The mitral valve and LV cavity were explored through LA approach. Ablation catheter entrapment in several chordae of first posterior leaflet of mitral valve (Figure 1C) was confirmed. We found no chordae rupture or damage to the mitral valve. The entrapped catheter was released and removed. Myocardial bridge of the left anterior descending artery was observed and myomectomy was performed. Only trivial mitral regurgitation was noted after surgery. The patient tolerated the entire procedure well and was discharged uneventfully 7 days later. The patient received another successful ablation 3 months later. Forcible traction of the entrapped catheter may damage the valve, leading to acute mitral insufficiency and requiring mitral valve replacement. In the previously published case reports,1, 2 when gentle traction of the catheter was ineffective, the strategy to release an entangled catheter was advancement of the catheter apically toward the papillary muscle and away from chordal components, so as to liberate the catheter tip. The catheter advancement approach involves possible damage to the mitral apparatus. Pulling under echocardiographic guidance is a safer strategy if the catheter location is unclear fluoroscopically. Some reports have suggested that if catheter entrapment cannot be resolved with gentle manipulation and moderate traction, as we first attempted in this case, open heart surgery may be the best option for removing the catheter. We took action mindful of the findings of previously reported cases. We immediately performed periprocedural transesophageal echocardiogram to confirm the location of the entrapped catheter. We conclude that by avoiding blinded traction, the disruption of the mitral valvular structures can be minimized and the complexity of any necessary surgery reduced. All authors declare no conflict of interest.
No takes yet. Share an insight, caveat, or question.
Lin et al. (2021) conducted a case report in Ablation catheter entrapment in the mitral valve (n=1). Periprocedural transesophageal echocardiogram and emergent surgery was evaluated on Successful removal of entrapped catheter.
Synapse has enriched 10 related papers. Consider them for comparative context: