Answers are grounded in this paper and cite their sources.
The n-channel LDD MOSFET lifetime is observed to followτ=(A/Id)(Isub/Id)⁻ⁿfrom 77 to 295 K when the device is stressed near the maximum Isub. Here Idis the drain current andAis the proportionality constant. The experimental result indicates thatnis approximately 2.7 and is independent of temperature. However, the proportionality constantAfollowsA = A₀ exp (-Eₐ/kT), withEₐ = 39meV. The smaller proportionality constant at low temperatures suggests that hot-electron injection (HEI) degradation is caused by the electron trapping in the oxide.
No takes yet. Share an insight, caveat, or question.
Tzou et al. (1985) studied this question.