Answers are grounded in this paper and cite their sources.
A GaAs MESFET E-D invertor was analysed to estimate the optimum threshold voltage VT for a switching FET, and the optimum load current IL for a load FET, that will minimise the invertor switching time. The calculated results show that the optimum VT lies at around 0.2 V, and the optimum IL is about 55% of the saturation current of the switching FET.
No takes yet. Share an insight, caveat, or question.
Ino et al. (1981) studied this question.