Answers are grounded in this paper and cite their sources.
This article addresses a fundamental issue in power converter control. Namely, the direct output-voltage control of power converters with higher order dynamics. We argue that despite of the burst in the development of new topologies, legacy control design principles—inherited from second-order converter analysis— have been unduly adopted asde factorules of procedure. In particular, we refer to the minimum-phase requirement on the feedback variable, as the underlying stabilizing mechanism. In this article, we demonstrate that the requirement of minimum-phaseness for higher order converters and the legacyad hocsolution via ancillary current control, can be bypassed without compromising closed-loop performance. To prove this, we unveil important differences between stability properties of second-order and higher order converters. Then, we introduce new linear and nonlinear control design strategies that permit direct output-voltage control. Experimental results are provided to validate the theory.
No takes yet. Share an insight, caveat, or question.
Garza-Arias et al. (2022) studied this question.