Key result
A re-trained deep learning algorithm correctly performed 95.5% of aortic diameter measurements on non-ECG-gated chest CT exams, improving upon the initial version.
Why the study?
Automated thoracic aortic dilatation classification on non-ECG gated CT is frequently unreliable, especially at the aortic root, prompting evaluation of algorithm retraining.
Does a re-trained deep learning algorithm improve the accuracy of aortic diameter measurements on non-gated chest CT in patients with thoracic aortic dilatation?
Observational (n=995)
Does a re-trained deep learning algorithm improve the accuracy of aortic diameter measurements on non-gated chest CT in patients with thoracic aortic dilatation?
Retraining a deep learning algorithm significantly improved the accuracy of automated aortic diameter measurements on non-ECG-gated chest CTs, achieving 95.5% correct measurements.
Answers are grounded in this paper and cite their sources.
DL TAD detection on non-gated CT remains unreliable at the aortic root; leaves open need for ECG-gating or refined algorithms before routine use.
PURPOSE/OBJECTIVE: Reliable detection of thoracic aortic dilatation (TAD) is mandatory in clinical routine. For ECG-gated CT angiography, automated deep learning (DL) algorithms are established for diameter measurements according to current guidelines. For non-ECG gated CT (contrast enhanced (CE) and non-CE), however, only a few reports are available. In these reports, classification as TAD is frequently unreliable with variable result quality depending on anatomic location with the aortic root presenting with the worst results. Therefore, this study aimed to explore the impact of re-training on a previously evaluated DL tool for aortic measurements in a cohort of non-ECG gated exams. METHODS & MATERIALS: A cohort of 995 patients (68 ± 12 years) with CE (n = 392) and non-CE (n = 603) chest CT exams was selected which were classified as TAD by the initial DL tool. The re-trained version featured improved robustness of centerline fitting and cross-sectional plane placement. All cases were processed by the re-trained DL tool version. DL results were evaluated by a radiologist regarding plane placement and diameter measurements. Measurements were classified as correctly measured diameters at each location whereas false measurements consisted of over-/under-estimation of diameters. RESULTS: We evaluated 8948 measurements in 995 exams. The re-trained version performed 8539/8948 (95.5%) of diameter measurements correctly. 3765/8948 (42.1%) of measurements were correct in both versions, initial and re-trained DL tool (best: distal arch 655/995 (66%), worst: Aortic sinus (AS) 221/995 (22%)). In contrast, 4456/8948 (49.8%) measurements were correctly measured only by the re-trained version, in particular at the aortic root (AS: 564/995 (57%), sinotubular junction: 697/995 (70%)). In addition, the re-trained version performed 318 (3.6%) measurements which were not available previously. A total of 228 (2.5%) cases showed false measurements because of tilted planes and 181 (2.0%) over-/under-segmentations with a focus at AS (n = 137 (14%) and n = 73 (7%), respectively). CONCLUSION: Re-training of the DL tool improved diameter assessment, resulting in a total of 95.5% correct measurements. Our data suggests that the re-trained DL tool can be applied even in non-ECG-gated chest CT including both, CE and non-CE exams.
No takes yet. Share an insight, caveat, or question.
Piccolo et al. (2023) conducted an observational in Thoracic aortic dilatation (n=995). Re-trained deep learning algorithm vs. Initial deep learning algorithm was evaluated on Correctly measured aortic diameters. A re-trained deep learning algorithm correctly performed 95.5% of aortic diameter measurements on non-ECG-gated chest CT exams, improving upon the initial version.
Synapse has enriched 10 related papers. Consider them for comparative context: