Key result
In a 40-year-old man with repaired tetralogy of Fallot and infra-Hisian Wenckebach block, permanent dual-chamber pacemaker implantation resulted in freedom from symptoms over 18 months of follow-up.
Case Report (n=1)
Wenckebach type block can occur at the infra-Hisian level in patients with repaired tetralogy of Fallot, highlighting the need for careful electrophysiological evaluation and potential pacemaker implantation in this aging population.
Answers are grounded in this paper and cite their sources.
Pacing may relieve symptoms in repaired tetralogy of Fallot with infra-Hisian Wenckebach; leaves open prospective evaluation of indications in this population.
A 40-year-old man was admitted to our intensive care unit after a first episode of syncope. He had undergone surgery 35 years back for tetralogy of Fallot. Clinical examination revealed an occasionally missing pulse and a moderate diastolic pulmonary murmur, without evidence of any signs of cardiac failure. Routine haematological and biochemical investigations were within normal limits. The initial surface ECG demonstrated the presence of several patterns of atrioventricular (AV) and intraventricular conduction disturbance: right bundle branch block, left anterior hemiblock, and prolonged PR interval with varying Wenckebach periodics of 3:2 and 4:3 conduction ratios ( Figure 1 A ). Simple clinical testing, such as moving in bed, provoked dramatic worsening with a high-degree block and lipothymia ( Figure 1 B ). Carotid sinus massage had no effect on AV conduction. Baseline electrophysiological studies demonstrated a constant and normal AH interval and H wave. In contrast, the HV interval showed typical Wenckebach periodicity, with progressive prolongation until block after H potential ( Figure 1 C ). The patient was advised to undergo permanent dual-chamber pacemaker implantation and remained free of symptoms during the first 18 months of follow-up. ( A ) ECG showing the presence of a sinus rhythm with a large right bundle branch block (QRS, 160 ms) with left axial deviation. In addition, the PR interval was prolonged with varying Wenckebach blocks of 3:2 and 4:3 conduction ratios. Note that this type of right bundle branch is a common ECG feature after surgery for tetralogy of Fallot. ( B ) Moderate exercise increased the sinus rate (cycle of 660 ms) and resulted in a dramatic worsening of AV conduction with 3:1 periods, clearly in favour of a distal AV block. ( C ) Electrophysiological investigations proved that the PR progressive (Wenckebach periods) increment was secondary to HV prolongation (54, 72, and 87 ms until block after H potential) and not to AH prolongation as usually reported. Mobitz 1 AV block, usually considered to be benign, normally occurs at the AV node level, with stable escape rhythm in the case of complete block. However, as demonstrated here, decremental conduction at the His or infra-His level may also occur. Finally, as many patients with repaired tetralogy of Fallot enter middle or old age, the need for continued surveillance and informed cardiac care is evident, because of the risk of the AV block and ventricular arrhythmias. Conflict of interest : none declared.
No takes yet. Share an insight, caveat, or question.
Marijon et al. (2008) conducted a case report in Repaired tetralogy of Fallot with syncope and AV block (n=1). Permanent dual-chamber pacemaker implantation was evaluated on Symptom recurrence. In a 40-year-old man with repaired tetralogy of Fallot and infra-Hisian Wenckebach block, permanent dual-chamber pacemaker implantation resulted in freedom from symptoms over 18 months of follow-up.
Synapse has enriched 10 related papers. Consider them for comparative context: