Answers are grounded in this paper and cite their sources.
We demonstrate enhanced radio frequency (RF) detection sensitivity in a magnetic tunnel junction based spin torque oscillator (STO) using parametric synchronization. The parametric synchronization is observed above the auto-oscillation threshold of the STO and enhances the RF sensitivity at 2f0, where f0 is the auto-oscillation frequency. The maximum RF sensitivity for parametric synchronization at 2f0≃9 GHz is 16 mV/mW, while the maximum RF sensitivity at f0≃4.5 GHz without parametric synchronization is 12 mV/mW. Macrospin simulations corroborate the experimental results.
No takes yet. Share an insight, caveat, or question.
Tiwari et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: