Key result
Prolonging atrioventricular delay in patients with DDD pacemakers revealed a significant negative correlation between critical PQ intervals inducing diastolic MR and PCWP.
Why the study?
Does prolonging AV delay induce diastolic mitral regurgitation and how does it relate to cardiac function in patients with DDD pacemakers?
Observational (n=50)
Does prolonging AV delay induce diastolic mitral regurgitation and how does it relate to cardiac function in patients with DDD pacemakers?
The appearance of diastolic mitral regurgitation during AV delay prolongation in DDD pacemaker patients is strongly correlated with baseline cardiac function as measured by PCWP.
Answers are grounded in this paper and cite their sources.
Diastolic MR with AV delay prolongation may signal higher PCWP in DDD pacemaker patients; leaves open whether this marker guides optimization.
Diastolic mitral regurgitation (MR) is known to be induced by prolonging atrioventricular (AV) delay in patients implanted with a DDD pacemaker. We studied the relationship between diastolic MR and PQ intervals on cardiac function in 50 patients (71.3 +/- 11.3 years old: mean +/- SD), who had been implanted with DDD pacemakers. In 19 patients, prior to pacemaker implantation, pulmonary capillary wedge pressure (PCWP) was measured using a Swan-Ganz catheter during AV sequential pacing with an AV delay of 0.165 seconds. Transmitral blood flow was measured with pulsed Doppler echocardiography, while prolonging AV delay stepwise by 0.025 seconds from 0.065 seconds for about 5 minutes each. In nine patients, AV delay could not be prolonged enough due to occurrence of intrinsic AV conduction. In the other 41 patients, diastolic MR was induced by prolonging AV delay. The critical PQ intervals that induced diastolic MR ranged from 0.14 to 0.26 (0.23 +/- 0.03) seconds. Four of five patients whose critical PQ intervals were 0.20 seconds or shorter had heart failure, while 36 patients whose critical PQ intervals were greater than 0.20 seconds were free from signs and symptoms of heart failure. Their PCWPs were 2-27 (7.5 +/- 5.1) mmHg. There was a significant negative correlation between the critical PQ intervals for the appearance of diastolic MR and PCWP during AV sequential pacing, which was performed prior to pacemaker implantation (r = -0.85, P less than 0.001). It is suggested that the appearance of diastolic MR is determined mainly by PQ intervals and cardiac function.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Ishikawa et al. (1991) conducted an observational in Patients implanted with DDD pacemakers (n=50). Prolonging atrioventricular (AV) delay was evaluated on Correlation between critical PQ intervals for the appearance of diastolic MR and PCWP (r = -0.85, p=<0.001). Prolonging atrioventricular delay in patients with DDD pacemakers revealed a significant negative correlation between critical PQ intervals inducing diastolic MR and PCWP.
Synapse has enriched 10 related papers. Consider them for comparative context: