Key result
Measurement of grey scale median in carotid plaques using Artery Measurement System yielded higher values compared to Adobe Photoshop.
Why the study?
Does the choice of software (AMS vs Adobe Photoshop) affect the measurement of Grey Scale Median (GSM) in ultrasound images of carotid plaques?
Observational (n=100)
Does the choice of software (AMS vs Adobe Photoshop) affect the measurement of Grey Scale Median (GSM) in ultrasound images of carotid plaques?
Although absolute GSM values differ significantly between Adobe Photoshop and AMS, they show good correlation, highlighting the need for standardized software and methods in carotid plaque ultrasound analysis.
Answers are grounded in this paper and cite their sources.
May affect GSM interpretation in carotid plaque analysis; leaves open need for software standardization in research.
Grey scale median (GSM) measured on ultrasound images of carotid plaques has been used for several years now in research to find the vulnerable plaque. Centres have used different software and also different methods for GSM measurement. This has resulted in a wide range of GSM values and cut-off values for the detection of the vulnerable plaque. The aim of this study was to compare the values obtained with two different softwares, using different standardization methods, for the measurement of GSM on ultrasound images of carotid human plaques. GSM was measured with Adobe Photoshop(®) and with Artery Measurement System (AMS) on duplex ultrasound images of 100 consecutive medium- to large-sized carotid plaques of the Beta-blocker Cholesterol-lowering Asymptomatic Plaque Study (BCAPS). The mean values of GSM were 35·2 ± 19·3 and 55·8 ± 22·5 for Adobe Photoshop(®) and AMS, respectively. Mean difference was 20·45 (95% CI: 19·17-21·73). Although the absolute values of GSM differed, the agreement between the two measurements was good, correlation coefficient 0·95. A chi-square test revealed a kappa value of 0·68 when studying quartiles of GSM. The intra-observer variability was 1·9% for AMS and 2·5% for Adobe Photoshop. The difference between softwares and standardization methods must be taken into consideration when comparing studies. To avoid these problems, researcher should come to a consensus regarding software and standardization method for GSM measurement on ultrasound images of plaque in the arteries.
No takes yet. Share an insight, caveat, or question.
Östling et al. (2013) conducted an observational in Carotid plaques (n=100). Artery Measurement System (AMS) vs. Adobe Photoshop was evaluated on Grey scale median (GSM) measurement (MD 20.45, 95% CI 19.17-21.73). Measurement of grey scale median in carotid plaques using Artery Measurement System yielded higher values compared to Adobe Photoshop.
Synapse has enriched 10 related papers. Consider them for comparative context: