Key result
Absolute beat-to-beat variability and instability parameters of repolarization predicted ischaemia-induced ventricular fibrillation with high sensitivity and specificity in rat hearts.
Why the study?
Do absolute beat-to-beat variability and instability (BVI) parameters predict ischaemia-induced ventricular fibrillation in Langendorff-perfused rat hearts?
Do absolute beat-to-beat variability and instability (BVI) parameters predict ischaemia-induced ventricular fibrillation in Langendorff-perfused rat hearts?
Absolute beat-to-beat variability and instability parameters of repolarization can accurately predict ischaemia-induced ventricular fibrillation in a preclinical rat model, suggesting utility as biomarkers in drug assessment.
Answers are grounded in this paper and cite their sources.
Supports BVI parameters as VF biomarkers in rat ischaemia models; leaves open translation to humans or drug screening.
BACKGROUND AND PURPOSE: Predicting lethal arrhythmia liability from beat-to-beat variability and instability (BVI) of the ECG intervals is a useful technique in drug assessment. Most investigators use only arrhythmia-free ECGs for this. Recently, it was shown that drug-induced torsades de pointes (TdP) liability can be predicted more accurately from BVI measured irrespective of rhythm, even during arrhythmias (absolute BVI). The present study tested the broader applicability of this assessment by examining whether absolute BVI parameters predict another potential lethal arrhythmia, ischaemia-induced ventricular fibrillation (VF). EXPERIMENTAL APPROACH: Langendorff-perfused rat hearts were subjected to regional ischaemia for 15 min. Absolute BVI parameters were derived from ECG intervals measured in 40 consecutive ventricular complexes (irrespective of rhythm) immediately preceding VF onset and compared with time-matched values in hearts not expressing VF. KEY RESULTS: Increased frequency of non-sinus beats and 'R on T' arrhythmic beats, shortened mean RR and electrical diastolic intervals, and increased BVI of cycle length and repolarization predicted VF occurrence. Absolute BVI parameters that quantify variability of repolarization (e.g. 'short-term variability' of QT interval) had the best predictive power with high sensitivity and specificity. In contrast, VF was not predicted by any BVI parameter derived from the last arrhythmia-free interlude before VF. CONCLUSIONS AND IMPLICATIONS: The novel absolute BVI parameters that predicted TdP in rabbit also predict ischaemia-induced VF in rat, indicating a diagnostic and mechanistic congruence. Repolarization inhomogeneity represents a pivotal biomarker of ischaemia-induced VF. The newly validated biomarkers could serve as surrogates for VF in pre-clinical drug investigations.
No takes yet. Share an insight, caveat, or question.
Sarusi et al. (2014) studied Ischaemia-induced ventricular fibrillation. Absolute beat-to-beat variability and instability (BVI) parameters vs. Time-matched values in hearts not expressing VF was evaluated on Prediction of ischaemia-induced ventricular fibrillation (VF). Absolute beat-to-beat variability and instability parameters of repolarization predicted ischaemia-induced ventricular fibrillation with high sensitivity and specificity in rat hearts.
Synapse has enriched 10 related papers. Consider them for comparative context: