Answers are grounded in this paper and cite their sources.
Fluorine-containing wastewater from the Yuncheng Sewage Treatment Plant in Heze City, Shandong Province was treated by coagulation and precipitation with poly aluminum sulfate, and CaO chemical precipitation-activated carbon adsorption, with a view to reducing fluoride ions concentration in the wastewater to below the discharge standard.The results showed that the optimum conditions for the coagulation-sedimentation test of poly aluminum sulfate were as follows: the dosage of poly aluminum sulfate 0.3 g/dm 3 , initial pH value 4.0, the removal rate of fluoride ion in the fluorine-containing wastewater reached 98.46%, and the concentration of fluoride ion was 0.462 mg/dm 3 , which reached the discharge standard (1.5 mg/dm 3 ); The optimum conditions for the CaO chemical precipitation, and lanthanum loaded activated carbon adsorption method were as follows: the amount of CaO 20 g/dm 3 , initial pH of the chemical precipitation test 8.0, the dosage of lanthanum loaded activated carbon 10 g/dm 3 , and the initial pH of the adsorption test 6.0.At this time, the removal rate of fluoride ions in the fluorine-containing wastewater reached 95.81%, and the concentration of fluoride ions was 1.26 mg/dm 3 , which also met the discharge standard.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: