Answers are grounded in this paper and cite their sources.
Highly oriented single-crystal ZnO nanotube (ZNT) arrays were prepared by a two-step electrochemical/chemical process on indium-doped tin oxide (ITO) coated glass in an aqueous solution. The prepared ZNT arrays were further used as a working electrode to fabricate an enzyme-based glucose biosensor through immobilizing glucose oxidase in conjunction with a Nafion coating. The present ZNT arrays-based biosensor exhibits high sensitivity of 30.85 μA cm −2 mM −1 at an applied potential of +0.8 V vs. SCE, wide linear calibration ranges from 10 μM to 4.2 mM, and a low limit of detection (LOD) at 10 μM (measured) for sensing of glucose. The apparent Michaelis−Menten constant K M app was calculated to be 2.59 mM, indicating a higher bioactivity for the biosensor.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2009) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: