Key result
Aortic valve replacement with the Perceval sutureless bioprosthesis resulted in a 0% incidence of patient-prosthesis mismatch compared to 61.3% with conventional sutured valves.
Why the study?
Does sutureless aortic valve replacement with the Perceval bioprosthesis reduce the incidence of patient-prosthesis mismatch compared to conventional sutured bioprosthesis in patients with severe symptomatic aortic stenosis?
Cohort (n=242)
Yes
Does sutureless aortic valve replacement with the Perceval bioprosthesis reduce the incidence of patient-prosthesis mismatch compared to conventional sutured bioprosthesis in patients with severe symptomatic aortic stenosis?
Sutureless aortic valve replacement with the Perceval bioprosthesis significantly increases the indexed effective orifice area and eliminates patient-prosthesis mismatch compared to conventional sutured valves in matched patients with severe aortic stenosis.
Answers are grounded in this paper and cite their sources.
May reduce PPM after aortic valve replacement; hypothesis-generating and requires randomized confirmation before practice change.
OBJECTIVES: The aim of this study is to compare the theoretical incidence of patient-prosthesis mismatch (PPM) in patients undergoing a sutureless or a sutured aortic valve replacement using an exact statistical matching. METHODS: Between May 2012 and March 2016, 65 patients with severe symptomatic aortic stenosis underwent a sutureless aortic valve replacement with the Perceval bioprosthesis in 2 centres. Moreover, 177 aortic valve replacements with conventional sutured bioprosthesis were performed between August 2003 and September 2015. Perceval and sutured patients were 1:1 exactly matched for sex and body surface area (BSA), resulting in 62 couples (sutureless: BSA 1.77 ± 0.16 m 2 , female 62.9% vs sutured: BSA 1.77 ± 0.15 m 2 , female 62.9%). RESULTS: After matching, the indexed effective orifice area was 1.50 ± 0.18 cm 2 /m 2 and 0.81 ± 0.19 cm 2 /m 2 in the sutureless and the sutured group, respectively ( P < 0.001). No PPM occurred in patients who received a Perceval bioprosthesis ( n = 62). In the sutured group ( n = 62), 38 patients (61.3%) developed a PPM, which was moderate in 41.9% ( n = 26) and severe in 19.4% ( n = 12) ( P < 0.001). CONCLUSIONS: The indexed effective orifice area of the sutureless group was significantly larger than in the sutured one. The incidence of PPM with the conventional sutured biprosthesis was 61.3%, while it decreases to 0% in the sutureless group. No PPM was reported in the sutureless valve group. Therefore, the Perceval sutureless valve provides larger effective orifice areas compared to the sutured conventional bioprosthesis and could be considered as a good option to reduce the risk of a PPM.
No takes yet. Share an insight, caveat, or question.
Belluschi et al. (2017) conducted a cohort in severe symptomatic aortic stenosis (n=242). Perceval sutureless bioprosthesis vs. Conventional sutured bioprosthesis was evaluated on Patient-prosthesis mismatch (PPM) (p=<0.001). Aortic valve replacement with the Perceval sutureless bioprosthesis resulted in a 0% incidence of patient-prosthesis mismatch compared to 61.3% with conventional sutured valves.