Why the study?
Does two-dimensional echocardiography accurately measure right ventricular function compared to blood pool scan in patients with acute myocardial infarction?
Does two-dimensional echocardiography accurately measure right ventricular function compared to blood pool scan in patients with acute myocardial infarction?
Fractional shortening of the minor axis in the apical four-chamber view using 2D echocardiography is a reliable and accurate method for evaluating right ventricular function and identifying right ventricular infarction in patients with acute MI.
Answers are grounded in this paper and cite their sources.
Apical four-chamber fractional shortening may aid RV assessment in acute MI; leaves open prospective validation against contemporary modalities.
Twenty-five patients with acute myocardial infarction, 15 inferior wall (IWMI) and 10 anterior wall (AWMI), were studied using two-dimensional echocardiography (2DE) and blood pool scan to evaluate the accuracy of 2DE for measuring right ventricular function. Fractional shortening (FS) of the minor axis of the right ventricle in the apical four chamber view (A4C) and subcostal four chamber view (S4C) for AWMI patients was higher as compared to the control group (41.8± 11 vs 27±9 and 46±8 vs 27±7 respectively). FS of the minor right ventricular axis for isolated IWMI subjects in the same views was not significantly different from the control population (32±7% vs 27±9% and 34± 13 vs 27±7% respectively). However, patients with an IWMI complicated by right ventricular infarction (RVI) had a significant depression of FS of the minor axis as compared to the control group in both the A4C and S4C views (8±5% vs 27±9% and 18±7 vs 27±7% respectively). FS of the minor axis in only the A4C view correlated . well with the corresponding blood pool scan ejection fraction (EF) for the entire infarction group (r=.69, p<.001). Long axis FS was not significantly different from controls for the IWMI and AWMI group and the correlation with the blood pool scan EF was poor (r= .32 and r=.09 respectively). Surface area of the right ventricle in the A4C view was increased in four of six patients with RVI and six of six patients with blood pool scans. FS of the minor axis in the A4C view correlated well with right ventricular function and was accurate in identifying those patients with an RVI. FS of the long axis was not a reliable measurement for evaluating right ventricular function. Surface area determination of the right ventricular cavity did not prove to be a sensitive index of right ventricular function in addition.
No takes yet. Share an insight, caveat, or question.
Stephen Arvan (1984) studied this question.