Key result
Electrical stimulation of the median nerve resulted in a statistically significant decrease in brachial artery flow rate (P<0.001) and diameter (P<0.001) in healthy volunteers.
Why the study?
The sympathetic nervous system regulates peripheral arteries by inducing vasospasm, motivating the creation of a noninvasive, repeatable Doppler ultrasound self-test model to evaluate its activity.
Does electrical stimulation of the median nerve reduce brachial artery diameter and flow rate in healthy participants?
Does electrical stimulation of the median nerve reduce brachial artery diameter and flow rate in healthy participants?
p-value: p=<0.001
Doppler ultrasonography can be used to noninvasively assess peripheral sympathetic nervous system function by measuring brachial artery responses to electrical stimulation.
Supports Doppler assessment of peripheral sympathetic function; hypothesis-generating in healthy adults and should not yet change practice.
BACKGROUND The sympathetic nervous system is principally accountable for peripheral artery regulation, and its effect is that vasospasm occurs in the medium and large arteries of the extremities, resulting in decreased flow of blood. Because of this information of how the body works, our goal is to create a noninvasive and repeatable self-test model that uses Doppler ultrasound examination. MATERIAL AND METHODS The study was conducted on 31 healthy and active participants who volunteered for the study. Written informed consent was obtained from all participants. The baseline diameter and flow rates of the brachial artery from 2 cm superior to the antecubital fossa were determined using a Doppler probe, which remained stationary throughout the experiment, allowing for continuous measurements. Then, to activate the sympathetic fibers, an electrical stimulus was applied for 5 s with an intensity of 10 mA and frequency of 1 Hz at the level of the median nerve at the wrist via the bipolar stimulation electrode. Immediately following the sixth stimulation, the artery diameter and flow rates were assessed again. RESULTS Following the stimulation, a statistically significant decrease in flow rate was observed (P<0.001). Moreover, stimulation resulted in a statistically significant reduction in the diameter of the brachial artery (P<0.001). CONCLUSIONS Our research suggests that Doppler ultrasonography can be routinely used to detect the normal and abnormal functioning of the peripheral sympathetic nervous system.
No takes yet. Share an insight, caveat, or question.
Kazcı et al. (2023) studied Healthy (n=31). Electrical stimulation of the median nerve vs. Baseline (pre-stimulation) was evaluated on Brachial artery flow rate and diameter (p=<0.001). Electrical stimulation of the median nerve resulted in a statistically significant decrease in brachial artery flow rate (P<0.001) and diameter (P<0.001) in healthy volunteers.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: