Key result
In patients undergoing transvenous lead extraction for device infection, dialysis was independently associated with increased mortality at 1 and 6 months (P<0.0001) despite similar procedural success (94%).
Why the study?
Does dialysis status affect procedural success and mortality in patients undergoing transvenous lead extraction for infected cardiac devices?
Cohort (n=1,420)
Does dialysis status affect procedural success and mortality in patients undergoing transvenous lead extraction for infected cardiac devices?
In patients with cardiac device infections, dialysis status does not reduce the procedural success of transvenous lead extraction but is independently associated with significantly increased short- and intermediate-term mortality.
Answers are grounded in this paper and cite their sources.
Dialysis independently signals higher short-term mortality after infected device extraction despite procedural success; leaves open whether targeted peri-procedural strategies improve survival.
Background: Cardiac implantable electronic device infections have been on the rise. A high-risk population is that with renal disease, especially dialysis. We aimed to assess procedural profiles and clinical outcomes of transvenous lead extraction for cardiac implantable electronic device infection based on renal disease status. Methods and Results: In 1420 consecutive patients undergoing transvenous lead extraction of infected cardiac implantable electronic devices (1996–2012), we assessed procedural profiles and clinical outcomes in 3 groups: normal renal function (group 1, n=1159), renal dysfunction not requiring dialysis (group 2, n=163), and dialysis (group 3, n=98). A total of 3182 infected leads were extracted. Dialysis patients had shorter lead dwell times and were less likely to require transvenous lead extraction tools but as likely to require femoral workstations. There were higher overall rates of procedure-related complications in dialysis patients (12% versus ≈6% in nondialysis) with no difference in the major complication rates ( P =not significant). Complete procedural success rates were 94%, 96%, and 94% in groups 1, 2, and 3, respectively ( P =not significant). There were 4 intraprocedural deaths in group 1 versus none in groups 2 and 3. Mortality rates were significantly higher in dialysis patients both at 1 and 6 months ( P <0.0001 for both). In multivariable analyses, dialysis status was independently associated with increased mortality risk at 1 and 6 months. Other factors associated with mortality were lead material retention, functional (New York Heart Association) class, and occurrence of procedural complications. Conclusions: In patients with cardiac implantable electronic device infection, dialysis status did not seem to add complexity to transvenous lead extraction but was independently associated with increased mortality at 1 and 6 months.
No takes yet. Share an insight, caveat, or question.
Barakat et al. (2018) conducted a cohort in Cardiac implantable electronic device infection (n=1,420). Dialysis vs. Normal renal function or renal dysfunction not requiring dialysis was evaluated on Complete procedural success (p=not significant). In patients undergoing transvenous lead extraction for device infection, dialysis was independently associated with increased mortality at 1 and 6 months (P<0.0001) despite similar procedural success (94%).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: